Telemedicine
Phonocardiography
A phonocardiograph for telemedicine and an algorithm that generates realistic synthetic heart-sound signals.
A phonocardiograph records the sounds of the heart so that they can be analysed, stored and sent to a doctor elsewhere. This work, with the University of Dhaka (Bangladesh), produced a phonocardiograph designed for telemedicine.
To test such devices and the software that analyses heart sounds, the team also developed an algorithm that generates synthetic heart-sound signals from a few parameters measured on real recordings (amplitude, heart rate and the interval between the two heart sounds). Compared with recordings from public databases, the synthetic signals matched closely, with correlations above 0.8 and heart-rate differences as small as 1.6%.
Publications
-
Phonocardiogram: a robust algorithm for generating synthetic signals and comparison with real life ones
Biomedical Signal Processing and Control 60, 101983 · Elsevier · 2020
The work presented in this paper aims to develop and implement a robust algorithm for generating synthetic phonocardiogram (PCG) signals based on characteristics obtained from real life signals. The purpose of this work is to identify a few set of parameters that can be linked to the physiological state of the heart. The mathematical model used in the synthesis of the signal was based on three coupled ordinary differential equations (ODE) proposed by Jabloun et al. (2013). The amplitude, S2S1 duration, and heart rate of the real life PCG signals were extracted and used in the synthesis of the signals. The real life PCG signals were obtained from the MITHSDB and AADHSDB databases from Massachusetts Institute of Technology and Aalborg University respectively. The signals were preprocessed using a second order Butterworth low pass filter of cutoff frequency of 500 Hz to obtain cleaner versions. The system of equations was numerically solved with the fourth-order Runge-Kutta method. These synthetic PCG signals were then compared with the real life PCG signals. The time domain correlations between the two sets of signals showed a good agreement between the two with values above 0.8 for all tested cases. The percentage differences in heart rate (beats per minutes), amplitude and S2S1 durations between the real life and synthesized PCG signals also showed a close match with percentage values as small as 1.61%, 2.27% and 4.51% for heart rate, amplitude and S2S1 duration respectively.
@article{kapen2020phonocardiogram, title = {Phonocardiogram: A robust algorithm for generating synthetic signals and comparison with real life ones}, volume = {60}, ISSN = {1746-8094}, url = {http://dx.doi.org/10.1016/j.bspc.2020.101983}, DOI = {10.1016/j.bspc.2020.101983}, journal = {Biomedical Signal Processing and Control}, publisher = {Elsevier BV}, author = {Tiam Kapen, Pascalin and Mohamadou, Youssoufa and Kouam Kouam, Serge Urbain and Momo, Foutse and Tchamda, André Rodrigue and Tchuen, Ghislain}, year = {2020}, pages = {101983} } -
Design and development of a phonocardiograph for telemedicine applications
Health and Technology 12(2), 453–463 · Springer · 2022
Cardiovascular diseases (CVDs) represent one of the leading causes of death in low income countries where there is in general an absence of necessary medical devices and access to qualified medical professionals, particularly in the rural areas. A simple device like the phonocardiograph (PCG) linking patients in these areas to city based qualified medical professionals through telemedicine could provide an important solution. In this paper, the design and development of a low cost, user-friendly phonocardiograph system for telemedicine applications is presented. The device is composed of three main parts namely, the acoustic sensor module, the audio amplifier module and the application software. The acoustic sensor module is made up of a chest piece and a microphone enclosed in an acoustic insulator. COMSOL Multiphysics software was used to simulate the transmission loss through the acoustic insulator to find the material and thickness that will provide of the optimal insulation. It was found that a combination of a 2 mm thickness of Poly Lactic Acid (PLA) with a 10 mm thickness of Polystyrene provided an optimal insulation. The microphone converts the sound waves from the chest piece into electrical signals. This signal is then filtered and amplified by the audio amplifier module and sent to a PC via its microphone input. Using the application software, the electrical signal is digitized and processed for visualization and analysis in situ or remotely. The developed system works in the frequency range of 20 Hz to 1 kHz, with amplification of up to 100 times, and a noise attenuation of 89%.
@article{mohamadou2022design, title = {Design and development of a phonocardiograph for telemedicine applications}, volume = {12}, ISSN = {2190-7196}, url = {http://dx.doi.org/10.1007/s12553-022-00646-x}, DOI = {10.1007/s12553-022-00646-x}, number = {2}, journal = {Health and Technology}, publisher = {Springer Science and Business Media LLC}, author = {Mohamadou, Youssoufa and Kapen, Pascalin Tiam and Momo, Foutse and Kamga, Alban Loique Kamga and Docna, Origène and Mohammad, Moniruzzaman and Ahmad, Maruf and Rabbani, Khondkar Siddique-e}, year = {2022}, pages = {453–463} }